Altera Avalon Verification IP Suite Manual do Utilizador Página 55

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 224
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 54
Public EventsProvides status response that arrives together with the data. The public event signals
indicate the status of the Masters request such as successful completion, timeout, or error.
Figure 6-4: Avalon-MM Slave BFM Block Diagram
Command Descriptor
Avalon-MM Slave BFM API
(Transaction Level Commands)
System Interconnect Fabric
(Transfer Level)
Avalon-MM Slave
Interface Driver
Response Descriptor
Client
Command
Queue
Internal
Command
Queue
Avalon-MM Interface
Monitor
command
command
waitrequest
waitrequest
HDL
HDL
response
Test Program
(HDL)
Device Under Test (DUT)
Avalon-MM Master Component
S
S
M
M
S
M
Avalon-MM Master Port
Avalon-MM Slave Port
SystemVerilog
SystemVerilog Testbench
Avalon-MM
Slave BFM
Public Events
Pending
Read and Write
Response Queue
Parameters
The Avalon-MM Slave BFM supports the full range of signals defined for the Avalon-MM slave interface.
The following table describes parameters you can customize the Avalon-MM slave interface.
Table 6-3: Parameters for the Avalon-MM Slave BFM
DescriptionLegal
Values
Default
Value
Parameter
Port Widths
Address width in bits.N/A32Address width
Altera Corporation
Avalon-MM Slave BFM
Send Feedback
6-7
Parameters
Vista de página 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 223 224

Comentários a estes Manuais

Sem comentários