The Nios II Custom Instruction Master BFM uses queues to manage instructions. You can use this BFM to
manage instructions in the following ways:
You can create instructions and push them into the instruction queue. The BFM then removes the
instructions out one-by-one and drives them on the interface.
You can insert the instructions simultaneously at the beginning of the simulation.
If there is no instruction to execute, the BFM drives unknown (X), except on the readra, readrb, and
writerc control ports which are driven high.
The results are inserted into a result queue. You can remove the result on an event basis, or at the end of
the simulation.
Parameters
Table 14-1: Custom Instruction Master BFM Parameter Settings
DescriptionLegal ValuesDefault
Value
Option
General
Specifies the number of operands to use.
0: no operands are used
1: use dataa port only
2: use dataa and datab ports
0,1,22Number of Operands to Use
Specifies the fixed length for multi-cycle mode.N/A2Fixed Length for Multi-cycle
Mode
Port Enables
When On, the interface includes a result pin.On/OffOnUse Result Port
When On, the interface can include a start pin, a done
pin , both pins, or neither pins. The result returns in
any of the following conditions:
With a start signalResult returns together with
an instruction.
Without a start signalResult returns with
instruction on the bus at every clock cycle.
With a done signalResult returns at any time.
Without a done signalResult returns at a fixed
cycle.
On/OffOffUse Multi-cycle Mode
When On, the interface includes a start pin.On/OffOnUsing start port
When On, the interface includes a done pin.On/OffOnUsing done port
When On, the interface includes a n pin.On/OffOffUse Extended Port
Specifies the width of the extended n port.N/A1Extended Port Width
When On, the interface includes the readra and a pins.On/OffOffUse Internal Register a