Packet Classifier Timestamp Field Location Signals
These signals must be aligned to the start of a packet.
Table E-6: Timestamp Field Location Signals for the Packet Classifier
DescriptionWidthDirectionSignal
Indicates the location of the timestamp
field.
16Outputtx_etstamp_ins_ctrl_out_offset_
timestamp
Indicates the location of the correction
field.
16Outputtx_etstamp_ins_ctrl_out_offset_
correction_field
Indicates the location of the checksum
field.
16Outputtx_etstamp_ins_ctrl_out_offset_
checksum_field
Indicates the location of the checksum
corrector field.
16Outputtx_etstamp_ins_ctrl_out_offset_
checksum_correction
Altera Corporation
Packet Classifier
Send Feedback
E-5
Packet Classifier Timestamp Field Location Signals
UG-01008