Packet Classifier Ingress Control Signals
Table E-4: Ingress Control Signals for the Packet Classifier
DescriptionWidthDirectionSignal
96-bit format of ingress timestamp that
holds data so that the output can align
with the start of an incoming packet.
96Inputtx_etstamp_ins_ctrl_in_ingress_
timestamp_96b
64-bit format of ingress timestamp that
holds data so that the output can align
with the start of an incoming packet.
64Inputtx_etstamp_ins_ctrl_in_ingress_
timestamp_64b
96-bit format of ingress timestamp that
holds data so that the output can align
with the start of an outgoing packet.
96Outputtx_etstamp_ins_ctrl_out_ingress_
timestamp_96b
64-bit format of ingress timestamp that
holds data so that the output can align
with the start of an outgoing packet.
64Outputtx_etstamp_ins_ctrl_out_ingress_
timestamp_64b
Assert this signal when timestamp is
required for the particular frame. This
signal must be aligned to the start of an
incoming packet.
1Inputtx_egress_timestamp_request_in_
valid
A width-configurable fingerprint that
correlates timestamps for incoming
packets.
4Inputtx_egress_timestamp_request_in_
fingerprint
Assert this signal when timestamp is
required for the particular frame. This
signal must be aligned to the start of an
outgoing packet.
1Outputtx_egress_timestamp_request_out_
valid
A width-configurable fingerprint that
correlates timestamps for outgoing
packets.
4Outputtx_egress_timestamp_request_out_
fingerprint
Determines the clock mode.
00: Ordinary clock
01: Boundary clock
10: End-to-end transparent clock
11: Peer-to-peer transparent clock
2Inputclock mode
Indicates whether or not a packet
contains CRC.
1: Packet contains CRC
0: Packet does not contain CRC
1Inputpkt_with_crc