Signal Name Direction Width Description
strobe_in/
strobe_io
Input/
Bidirectiona
l
1
Positive strobe from pin. If the pin
type is set to Input, the strobe_in
signal is used. If the pin type is set
to Bidirectional, the strobe_io
signal is used.
strobe_in_n/
strobe_io_n
Input/
Bidirectiona
l
1 Negative strobe from pin. This is
used if the Strobe Configuration
parameter is set to Differential or
Complementary. If the pin type is
set to Input, the strobe_in_n
signal is used. If the pin type is set
to Bidirectional, the strobe_io_n
signal is used.
Avalon Configuration Bus Interface Signals
The Altera PHYLite for Parallel Interfaces IP core exposes the Avalon-MM slave and Avalon-MM master
interfaces when you perform dynamic reconfiguration. Connect the Avalon-MM slave to either a master
in the core or the master interface of either an Altera PHYLite for Parallel Interfaces IP core or the Arria
10 External Memory Interfaces IP core to be placed in the same column. You can only connect the master
interface to the slave interface of an Altera PHYLite for Parallel Interfaces IP core or an Arria 10 External
Memory Interfaces IP core to be placed in the same column.
Table 21: Avalon-MM Master Interface Signals
Signal Name Direction Width Description
avl_clk Input 1 Avalon interface clock.
avl_reset_n Input 1 Reset input synchronous to avl_clk.
avl_read Input 1 Read request from io_aux. This signal is synchronous to
the avl_clk input.
avl_write Input 1 Write request from io_aux. This signal is synchronous to
the avl_clk input.
avl_byteenable Input 4 Controls which bytes should be written on avl_
writedata.
avl_writedata Input 32 Write data from io_aux. This signal is synchronous to the
avl_clk input.
avl_address Input 28 Address from io_aux. This signal is synchronous to the
avl_clk input.
avl_readdata Output 32 Read data to io_aux. This signal is synchronous to the
avl_clk input.
avl_writedata Input 32 Write data from io_aux. This signal is synchronous to
the avl_clk input.
ug_altera_phylite
2015.01.16
Avalon Configuration Bus Interface Signals