Altera 40-Gbps Ethernet MAC and PHY MegaCore Function Manual do Utilizador Página 137

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 199
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 136
Table 3-36: MAC Reset Register
Writing a 1’b1 to any of the reset register fields initiates the corresponding reset sequence.
Address Name Bit Description HW
Reset
Value
Access
0x121 MAC Reset
[1] The MAC TX reset register. 1’b0 RW
[0] The MAC RX reset register. 1’b0 RW
Table 3-37: PHY Reset Register
Writing a 1’b1 to any of the reset register fields initiates the corresponding reset sequence.
Address Name Bit Description HW
Reset
Value
Access
0x01d PHY reset
[2] The PMA reset register. 1’b0 RW
[1] The PCS TX reset register. 1’b0 RW
[0] The PCS RX reset register. 1’b0 RW
Related Information
Resets on page 3-54
3-90
MAC and PHY Reset Registers
UG-01088
2014.12.15
Altera Corporation
Functional Description
Send Feedback
Vista de página 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 198 199

Comentários a estes Manuais