Chapter 8: Qsys Design Example 8–9
Running Qsys
August 2014 Altera Corporation RapidIO MegaCore Function
User Guide
Connecting Unconnected Clocks
Information about the clocks in the system appears in the Connections, Name,
Description, and Clock columns.
Connect all clocks designated as unconnected in the Clock column. Click unconnected
in the Clock column to assign the clock to
clk_0
.
This instruction does not affect the rapidio_0.clk port, which you exported
previously. This port is designated exported in the Clock column.
1 You must ensure that you also connect the calibration clock (
cal_blk_clk
) to a clock
with the appropriate frequency range 10–125 MHz. In this example, the default
external clock,
clk_0
, is in this range.
Connecting System Components
In Qsys, clicking and hovering the mouse over the Connections column displays the
potential connection points between components, represented as dots connecting
wires. A filled dot shows that a connection is made; an open dot shows a potential
connection point that is not currently connected. Clicking a dot toggles the connection
status. To complete this design, create the connections listed in Table 8–6.
Table 8–6. Connect System Components
Make Connection From To
clk_0
clk_reset
rapidio_0
clock_reset
master_bfm
clk_reset
master_bfm_io
clk_reset
onchip_mem...
reset1
rapidio_0
mnt_master
rapidio_0
sys_mnt_slave
rapidio_0
io_read_master
onchip_mem...
s1
rapidio_0
io_write_master
onchip_mem...
s1
master_bfm
m0
rapidio_0
mnt_slave
rapidio_0
sys_mnt_slave
master_bfm_io
m0
rapidio_0
io_write_slave
rapidio_0
io_read_slave
onchip_mem...
s1