Page 28 Ports and Parameters
DQ (ALTDQ) and DQS (ALTDQS) Megafunctions November 2010 Altera Corporation
Table 18 shows the bidirectional ports for the ALTDQS megafunction.
Table 19 shows the parameters for the ALTDQS megafunction.
dqsundelayedout
No
Non-delayed outputs from the DQS pins. Width of bus is equal to number of
DQS
pins. The size of the output port is dependent on the
NUMBER_OF_DQS
parameter.
Note to Table 17:
(1) Available for Stratix II devices only.
Table 17. ALTDQS Megafunction Output Ports (Part 2 of 2)
Port Name Required Description
Table 18. ALTDQS Megafunction Bidirectional Ports
Port Name Required Description
dqs_padio[]
Yes
Bidirectional DQS pins. Width of bus is equal to number of DQS pins. The size
of the bidirectional port is dependent on the
NUMBER_OF_DQS
parameter.
dqsn_padio[]
No
Bidirectional DQSn pins. Width of bus is equal to number of DQSn pins. The
size of the bidirectional port is dependent on the
NUMBER_OF_DQS
parameter.
(1)
Note to Table 18:
(1) Available for Stratix II devices only.
Table 19. ALTDQS Megafunction Parameters (Part 1 of 4)
Parameter Type Required Description
DLL_PHASE_SHIFT
String Yes Specifies DLL phase shift. The values are
0
,
72
, or
90
.
DQS_OE_ASYNC_RESET
String No
Specifies whether the
dqs_areset
port clears, presets, or has no
effect on the oe register. The values are
CLEAR
,
PRESET
, or
NONE
. If
DQS_OE_ASYNC_RESET
parameter is specified to
CLEAR
or
PRESET
,
dqs_areset
port is required. If omitted, the default value
is
NONE
.
DQS_OE_POWER_UP
String No
Specifies power-up condition of the
oe
registers. The values are
HIGH
or
LOW
. If omitted, the default value is
LOW
.
DQS_OE_REGISTER_MODE
String No
Specifies whether the
oe
port is registered. The values are
REGISTER
or
NONE
. If omitted, the default value is
NONE
.
DQS_OE_SYNC_RESET
String No
Specifies whether the
dqs_sreset
port clears, presets, or has no
effect on the oe register. The values are
CLEAR
,
PRESET
, or
NONE
. If
DQS_OE_SYNC_RESET
parameter is specified to
CLEAR
or
PRESET
,
the
dqs_sreset
port is required. If omitted, the default value is
NONE
.
DQS_OPEN_DRAIN_OUTPUT
String No
Specifies whether to use open drain mode. The values are
TRUE
or
FALSE
. If omitted, the default value is
FALSE
.
DQS_OUTPUT_ASYNC_
RESET
String No
Specifies whether the
dqs_areset
port clears, presets, or has no
effect on the DQS output registers. The values are
CLEAR
,
PRESET
,
or
NONE
. If the
DQS_OUTPUT_ASYNC_RESET
port is specified to
CLEAR
or
PRESET
, the
dqs_areset
is required. If omitted, the
default value is
NONE
.
DQS_OUTPUT_POWER_UP
String No
Specifies power-up condition of DQS output registers. The values
are
HIGH
or
LOW
. If omitted, the default value is
LOW
.
Comentários a estes Manuais