Parameter Possible Values Default Value Description
functions this field is reserved and must be hardwired to
0x0000b. Four time value ranges are defined:
Range A: 50 us to 10 ms
Range B: 10 ms to 250 ms
Range C: 250 ms to 4 s
Range D: 4 s to 64 s
Bits are set to show timeout value ranges supported. The
function must implement a timeout value in the range
50 s to 50 ms. The following values specify the range:
None – Completion timeout programming is not
supported
0001 Range A
0010 Range B
0011 Ranges A and B
0110 Ranges B and C
0111 Ranges A, B, and C
1110 Ranges B, C and D
1111 Ranges A, B, C, and D
All other values are reserved. Altera recommends that
the completion timeout mechanism expire in no less
than 10 ms.
Implement
completion
timeout
disable
On/Off On For Endpoints using PCI Express version 2.1 or 3.0, this
option must be On. The timeout range is selectable.
When On, the core supports the completion timeout
disable mechanism via the PCI Express Device
Control Register 2. The Application Layer logic must
implement the actual completion timeout mechanism
for the required ranges.
Error Reporting
Table 3-5: Error Reporting
Parameter Value Default Value Description
Advanced
error
reporting
(AER)
On/Off Off When On, enables the Advanced Error Reporting (AER)
capability.
UG-01105_avmm
2014.12.15
Error Reporting
3-5
Parameter Settings
Altera Corporation
Send Feedback