A–4 Getting Started User Guide Altera Corporation
Transceiver Signal Integrity Development Kit, Stratix II GX Edition June 2006
General User Interfaces
1 To set a DIP switch in the open position, press the switch
towards the OPEN side of the user DIP switch bank. To set a DIP
switch in the closed position, press the switch towards the
number side of the DIP switch bank.
Table A–2. DIP Switch Signal Names and Descriptions Note (1)
DIP Switch Name Description Width
Board
Reference
Number
Connected
to FPGA Pin
Number
Read and write PMA
control
The switch is used to display or set the
controllable parameters. The values are
displayed in the 7-segment display, i.e.,
O = read VOD, preemphasis from the
transceiver
C = write VOD, preemphasis into the
transceiver
11 AH33
PMA controls Silkscreen number:
4 3 2
O O O – preemphasis (only main tap)
O O C – VOD
O C C – DC gain
C C C – equalization
The other silkscreen numbers are reserved.
After this combination is set,
push_button_PMA_control has to be
pressed to set the values.
3 2, 3, 4 AH32,
AF28,
AF27
Data pattern select The switch selects the data patterns.
Switch position-silkscreen number:
6 5
C O – PRBS23
O C – PRBS7
O O – high frequency
C C – reserved
25, 6 AJ34,
AJ33
Serial loopback The switch dynamically controls serial
loopback.
O = serial loopback ON
C = serial loopback OFF
17 AG29
Reserved — 1 8 AG28
Note to Table A-2:
(1) The C refers to the DIP switch in the closed position, and the O refers to the DIP switch in the open position.