VHDL Slave BFM
execute_read_addr_ready()
Mentor Verification IP AE AXI4-Lite User Guide, V10.3
259
April 2014
execute_read_addr_ready()
This procedure executes a read address ready by placing the ready argument value onto the
ARREADY signal. It will block (default) for one ACLK period.
Example
-- Set the ARREADY signal to 1 and block for 1 ACLK cycle
execute_read_addr_ready(1, 1, index, AXI4_PATH_6, axi4_tr_if_6(index));
Prototype
procedure execute_read_addr_ready
(
ready : in integer;
bfm_id : in integer;
path_id : in axi4_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t
);
Arguments
transaction_id Transaction identifier. Refer to “Overloaded Procedure
Common Arguments” on page 151 for more details.
non_blocking_mode (Optional) Nonblocking mode:
0 = Nonblocking
1 = Blocking (default)
bfm_id BFM identifier. Refer to “Overloaded Procedure Common
Arguments” on page 151 for more details.
path_id (Optional) Parallel process path identifier:
AXI4_PATH_0
AXI4_PATH_1
AXI4_PATH_2
AXI4_PATH_3
AXI4_PATH_4
Refer to “Overloaded Procedure Common Arguments” on
page 151 for more details.
tr_if Transaction signal interface. Refer to “Overloaded Procedure
Common Arguments” on page 151 for more details.
Returns
None