Offset Register Name Read/Write 31 13 12 11 10 9 8 7 6 5 4 3 2 1 0
6 control RW (2) SO
FT
WA
RE
RE
SE
T
QU
AD
WO
RD
DO
UB
LE
WO
RD
WC
ON
RC
ON
LE
EN
WE
EN
RE
EN
I_
EN
GO WO
RD
HW B
Y
T
E
7 — — Reserved (3)
Table 23-3 :
1. Writing zero to the status register clears the LEN, WEOP, REOP, and DONE bits.
2. These bits are reserved. Read values are undefined. Write zero.
3. This register is reserved. Read values are undefined. The result of a write is undefined.
status Register
The status register consists of individual bits that indicate conditions inside the DMA controller. The
status register can be read at any time. Reading the status register does not change its value.
Table 23-4: status Register Bits
Bit
Number
Bit
Name
Read/Write/
Clear
Description
0 DONE R/C A DMA transaction is complete. The DONE bit is set to 1 when
an end of packet condition is detected or the specified transac‐
tion length is completed. Write zero to the status register to
clear the DONE bit.
1 BUSY R The BUSY bit is 1 when a DMA transaction is in progress.
2 REOP R The REOP bit is 1 when a transaction is completed due to an
end-of-packet event on the read side.
3 WEOP R The WEOP bit is 1 when a transaction is completed due to an
end of packet event on the write side.
4 LEN R The LEN bit is set to 1 when the length register decrements to
zero.
readaddress Register
The readaddress register specifies the first location to be read in a DMA transaction. The readaddress
register width is determined at system generation time. It is wide enough to address the full range of all
slave ports mastered by the read port.
writeaddress Register
The writeaddress register specifies the first location to be written in a DMA transaction. The writead-
dress register width is determined at system generation time. It is wide enough to address the full range
of all slave ports mastered by the write port.
UG-01085
2014.24.07
Register Map
23-7
DMA Controller Core
Altera Corporation
Send Feedback