Program the Serial Flash Memory
5. Connect the USB-Blaster download cable to the active serial
configuration connector, J11.
6. Choose Add File and browse to the POF file.
7. Click Open.
8. Click Start. The user-programmable EPCS64 device is programmed
via the active serial header.
To load the program from the user-programmable EPCS64 device to the
Cyclone II device, follow these steps:
1. Power-down the board by setting the SW1 switch in the Off
position.
2. Perform a power-on reset by setting the SW1 switch in the On
position. This will load the user-programmable flash memory data
into the Cyclone II device.
Pre-Loaded, Factory-Programmed (Safe) EPCS64 Device
This section provides the steps to load the factory-created reference
design into factory-programmed (safe) EPCS64 device’s serial flash
memory via the active serial programming method.
To program the pre-loaded, factory-programmed (safe) EPCS64 device’s
serial flash memory using the Quartus II software, follow these steps:
1. Choose Programmer (Tools menu). The Chain1.cdf window
displays.
2. Scroll to Active Serial Programming in the Mode field.
3. To select the preloaded, factory-programmed EPCS64 device, set the
switch (J3) to the Up position.
4. Connect the USB-Blaster download cable to the active serial
configuration connector, J11.
5. Choose Add File and browse to the factory-programmed POF file.
6. Click Open.
7. Click Start. The factory-created reference design is loaded into the
factory-configuration region of the EPCS64 device via the active
serial header.