Link Width Maximum Link Rate Avalon Interface Width coreclkout_hip
×8 Gen1
128
125 MHz
×1
Gen2 64
125 MHz
×2
Gen2 64
125 MHz
×4 Gen2 128 125 MHz
pld_clk
coreclkout_hip can drive the Application Layer clock along with the pld_clk input to the IP core. The
pld_clk can optionally be sourced by a different clock than coreclkout_hip. The pld_clk minimum
frequency cannot be lower than the coreclkout_hip frequency. Based on specific Application Layer
constraints, a PLL can be used to derive the desired frequency.
Clock Summary
Table 6-3: Clock Summary
Name Frequency Clock Domain
coreclkout_hip
62.5, 125 or 250 MHz Avalon-ST interface between the Transaction and
Application Layers.
pld_clk
62.5, 125, or 250 MHz Application and Transaction Layers.
refclk 100 or 125 MHz SERDES (transceiver). Dedicated free running input
clock to the SERDES block.
reconfig_xcvr_clk
100 –125 MHz Transceiver Reconfiguration Controller.
hip_reconfig_clk
50–125 MHz Avalon-MM interface for Hard IP dynamic reconfi‐
guration interface which you can use to change the
value of read-only configuration registers at
run-time. This interface is optional. It is not
required for Arria 10 devices.
2014.12.15
pld_clk
6-7
Reset and Clocks
Altera Corporation
Send Feedback