Altera ALTPLL (Phase-Locked Loop) IP Core Manual do Utilizador Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 69
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
DescriptionTypeParameter
Specifies the modulus for the M counter. Provides direct
access to the internal PLL parameters. If the M parameter
is specified, all advanced parameters must be used. Values
range from 1 to 512. If omitted, the default is 0.
IntegerM
Specifies the initial value for the M counter. Provides direct
access to the internal PLL parameters. If the M_INITIAL
parameter is specified, all advanced parameters must be
used. Values range from 0 to 512. If omitted, the default
is 0.
IntegerM_INITIAL
Specifies the phase tap for the M counter. Values range
from 0 to 7. If omitted, the default is 0.
IntegerM_PH
Specifies the test source for the M counter. If omitted,
default is 5.
IntegerM_TEST_SOURCE
Specifies, in nanoseconds (ns), the time delay for the M
counter. Values range from 0 ns through 3 ns. If omitted,
the default is 0. This parameter is not available for Cyclone
II and Stratix II devices.
IntegerM_TIME_DELAY
Specifies the spread spectrum modulus for the M counter.
Provides direct access to the internal PLL parameters. If
the M2 parameter is specified, all advanced parameters must
be used. Values range from 1 to 512. If omitted, the value
is 1.
IntegerM2
Specifies the modulus for the N counter. Provides direct
access to the internal PLL parameters. If the N parameter
is specified, all advanced parameters must be used. Values
range from 1 to 512. If omitted, the default is 1.
IntegerN
Specifies, in nanoseconds (ns), the time delay for the N
counter. Values range from 0 ns through 3 ns. If omitted,
the default is 0. This parameter is not available for
Cyclone II and Stratix II devices.
IntegerN_TIME_DELAY
Specifies the spread spectrum modulus for the N counter.
Provides direct access to the internal PLL parameters. If
the N2 parameter is specified, all advanced parameters must
be used. Values range from 1 through 512. If omitted, the
default is 1.
IntegerN2