Altera ALTPLL (Phase-Locked Loop) IP Core Manual do Utilizador Página 41

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 69
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 40
DescriptionConditionPort Name
(6)
Clock enable port for the serial
scan chain. Available only for
Arria II GX, Cyclone III,
HardCopy III, and Stratix III
devices onwards.
Optionalscanclkena
Contains the data for the serial
scan chain. Not available for
Cyclone and Cyclone II devices.
Optionalscandata
Port that controls the serial scan
chain to read input from the
scandata port. Only available for
Arria GX, HardCopy II, Stratix II,
and Stratix II GX devices.
Optionalscanread
Port that controls the real-time
programming scan chain to write
to the PLL. Only available for
Arria GX, HardCopy II, Stratix II,
and Stratix II GX devices.
Optionalscanwrite
ALTPLL Output Ports
Table 17: ALTPLL Output Ports
DescriptionConditionPort Name
(7)
Specifies which clock is used as the
primary reference clock when the
clock switchover circuit initiates.
If the inclk0 is in use, the
activeclock port goes low. If the
inclk1 is in use, the activeclock
port goes high.
You can set the PLL to automati-
cally initiate the clock switchover
when the primary reference clock
is not toggling correctly, or you
can manually initiate the clock
switchover using the clkswitch
input port.
Optionalactivelock
The clock output of the PLL.Requiredc[]
(6)
Replace brackets, [], in the port name with integer to get the exact name. For example, inclk0, inclk1, c1_
ena, and e0_ena.
(7)
Replace the brackets, [], in the port name with an integer to get the exact name (for example, c0, c1, c3, e0,
e1, e2, enable1 and sclkout0).
Altera Corporation
ALTPLL (Phase-Locked Loop) IP Core User Guide
Send Feedback
41
ALTPLL Output Ports
ug-altpll
2014.08.18
Vista de página 40