Altera Stratix V Avalon-ST Manual do Utilizador Página 186

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 293
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 185
Error Signaling Messages
Table 11-3: Error Signaling Messages
Message
Root
Port
Endpoin
t
Generated by
Comments
App
Layer
Core Core (with
App Layer
input)
ERR_
COR
RX TX No Yes No In addition to detecting errors, a Root
Port also gathers and manages errors sent
by downstream components through the
ERR_COR, ERR_NONFATAL, AND
ERR_FATAL Error Messages. In Root
Port mode, there are two mechanisms to
report an error event to the Application
Layer:
serr_out output signal. When set,
indicates to the Application Layer that
an error has been logged in the AER
capability structure
aer_msi_num input signal. When the
Implement advanced error reporting
option is turned on, you can set aer_
msi_num to indicate which MSI is
being sent to the root complex when
an error is logged in the AER
Capability structure.
ERR_
NONFAT
AL
RX TX No Yes No
ERR_
FATAL
RX TX No Yes No
UG-01097_avst
2014.08.18
Error Signaling Messages
11-3
Transaction Layer Protocol (TLP) Details
Altera Corporation
Send Feedback