Chapter 6: Board Test System 6–19
Using the Board Test System
October 2010 Altera Corporation Stratix IV GT 100G Development Kit User Guide
■ Detected errors—Displays the number of data errors detected in the hardware.
■ Inserted errors—Displays the number of errors inserted into the transaction
stream.
■ Insert Error—Inserts a one-word error into the transaction stream each time you
click the button. Insert Error is only enabled during transaction performance
analysis.
■ Clear Errors—Resets the Detected errors and Inserted errors counters to zeros.
Status
These controls display current transaction performance analysis information collected
since you last clicked Start:
■ PLL lock—Shows the PLL locked or unlocked state.
■ Pattern sync—Shows the pattern synced or not synced state. The pattern is
considered synced when the start of the data sequence is detected.
■ TX and RX performance bars—Show the percentage of maximum theoretical data
rate that the requested transactions are able to achieve.
■ TX and RX performance—Shows throughput in decimal form.
■ MBps—Shows the number of megabytes of data analyzed per second for transmit
and receive.