Chapter 2: Getting Started 2–3
Factory Default Switch and Jumper Settings
October 2014 Altera Corporation MAX 10 FPGA (10M08S, 144-EQFP) Evaluation Kit
User Guide
5 User-defined On
6
BOOT_SEL: Use this switch to choose CFM0, CFM1, or
CFM2 image as the first image in a dual-image configuration.
If BOOT_SEL is set to low, the first boot image is CFM0
image, If set to high, the first boot image is the CFM1 or
CFM2 image. By default, the FPGA setting for this pin is tri-
stated.
On
Table 2–2. Default Jumper Settings
Jumper Function Setting
J6
Jumper for analog input channel #8. Default connection is to
GND.
Pins 2 and 3
J7
Jumper for analog input channel #7. Default connection is to
potentiometer.
Pins 2 and 3
Table 2–1. Default SW3 DIP Switch Settings (Part 2 of 2)
Switch Function
Default