System tab
Figure 2-61: JNEye System Options Window: System Tab
Output Directory—Specify an output directory for the simulation results according to the Output
Directory Mode setting.
Output Directory Mode
Sync with .jne file location—Automatically sets the output directory to the directory location
when .jne/.jneschm is created by a user with the Save or Save as command.
As specified in the Output Directory—Sets the output directory to the location specified in the
Output Directory text box.
Default Output Image Format—Set the default output image format to PNG, JPG, or GIF.
Jitter Sensing Sensitivity—Select the sensitivity of jitter detection when JNEye performs jitter
analysis (Beta feature in the 15.0 release). The selections are: Default, Ideal, Low, Medium, and
High. The Default setting is equivalent to the Ideal setting.
S-parameter Integrity Check—Use this entry to enable or disable channel integrity checking in
JNEye. The default setting is Enable. Choose Disable if JNEye has issues in opening or accessing an
S-parameter model.