Altera Corporation Quartus II Version 3.0 5–11
Perform the Production Diagnostic Tests Perform the Standard Tests
3. Click Auto-Detect. The Stratix, Stratix GX, and 2 EPC16 devices
display in the JTAG chain.
4. Change the programming file for the Stratix GX device:
a. Right-click the filename next to the Stratix GX device.
b. Browse to the standard SOFs directory.
c. Select the file GX40_User_IO.sof.
d. Click Open. Wait until the checksum field is updated.
5. Change the programming file for the Stratix device to
STX40_User_IO.sof using the steps described above. Wait until the
checksum field is updated.
6. Turn on the Program/Configure option for the Stratix and
Stratix GX devices. See Figure 5–15.
Figure 5–15. Quartus II Programmer for the User I/O Test
7. Click Start to configure both devices. When configuration is
complete for both devices, the GX_CONF_DONE (D7) and
S_CONF_DONE (D6) LEDs illuminate as shown in Figure 4–1 on
page 4–2.
8. Test the user I/O for the Stratix GX device by performing steps 1
through 12 in “Run the User I/O Test” on page 4–3.