Chapter 3: EthernetBlaster II Communications Cable Specifications 3–5
Operating Conditions
January 2014 Altera Corporation EthernetBlaster II Communications Cable User Guide
V
OL
3.3-V low-level output voltage V
CC(TARGET)
= 3.6 V, IOL = 1 mA 0.4 V
2.5-V low-level output voltage V
CC(TARGET)
= 2.625 V, IOL = 1 mA 0.4 V
1.8-V low-level output voltage V
CC(TARGET)
= 1.89 V, IOL = 1 mA 0.4 V
1.5-V low-level output voltage V
CC(TARGET)
= 1.57 V, IOL = 1 mA 0.4 V
1.2-V low-level output voltage V
CC(TARGET)
= 1.26 V, IOL = 2 mA 0.4 V
I
CC(SYS)
Operating current (No Load)
Typical I
CC(SYS)
= 350mA @
V
CC(SYS)
= 12 V
700 mA
Table 3–5. EthernetBlaster II Cable DC Operating Conditions (Part 2 of 2)
Symbol Parameter Conditions Min Max Unit