Chapter 4: Development Board Setup 4–3
Factory Default Switch and Jumper Settings
November 2012 Altera Corporation Arria V GT FPGA Development Kit
User Guide
To restore the switches to their factory default settings, perform the following steps:
1. Set DIP switch bank (SW4) to match Table 41 and Figure 4–2.
2. Set DIP switch bank (SW5) to match Table 42 and Figure 4–2.
Table 4–1. SW4 FPGA2 MSEL Dip Switch Settings
(1)
Switch
Board
Label
Function
Default
Position
1 FPGA2_MSEL[1]
Switch 1 has the following options:
When ON, a logic 0 is selected.
When OFF, a logic 1 is selected.
ON
2 FPGA2_MSEL[2]
Switch 2 has the following options:
When ON, a logic 0 is selected.
When OFF, a logic 1 is selected.
OFF
3— ON
4 FPGA2_MSEL[4]
Switch 4 has the following options:
When ON, a logic 0 is selected.
When OFF, a logic 1 is selected.
OFF
Note to: Table 4–1
(1) Ensure that all MSEL setting are in a defined configuration scheme as shown in Volume 2: Device Interfaces and
Integration of the Arria V Device Handbook.
Table 4–2. SW5 Board Settings Dip Switch
Switch
Board
Label
Function
Default
Position
1 CLK_SEL
Switch 1 has the following options:
ON, (logical 0) = SMA input clock select.
OFF, (logical 1) = programmable oscillator clock select.
OFF
2 CLK_EN
Switch 2 has the following options:
ON, (logical 0) = on-board oscillator disable.
OFF, (logical 1) = on-board oscillator enable.
ON
3Factory1
Switch 3 has the following options:
ON, (logical 0) = load the factory design for Arria V
FPGA 1 from flash at power up.
OFF, (logical 1) = load the user design for Arria V FPGA
1 from flash at power up.
ON
4 Factory2 Switch 4 is for factory test only. OFF