Table 14-12: Log Messages
Constant
(Message
Type)
Description Mask Bit
No
Display
by Default
Simulation
Stops by
Default
Message
Prefix
EBFM_
MSG_
DEBUG
Specifies debug messages. 0 No No
DEBUG:
EBFM_
MSG_
INFO
Specifies informational
messages, such as configura‐
tion register values, starting
and ending of tests.
1 Yes No
INFO:
EBFM_
MSG_
WARNIN
G
Specifies warning messages,
such as tests being skipped
due to the specific configura‐
tion.
2 Yes No
WARNING:
EBFM_
MSG_
ERROR_
INFO
Specifies additional informa‐
tion for an error. Use this
message to display prelimi‐
nary information before an
error message that stops
simulation.
3 Yes No
ERROR:
EBFM_
MSG_
ERROR_
CONTIN
UE
Specifies a recoverable error
that allows simulation to
continue. Use this error for
data miscompares.
4 Yes No
ERROR:
EBFM_
MSG_
ERROR_
FATAL
Specifies an error that stops
simulation because the error
leaves the testbench in a state
where further simulation is
not possible.
N/A Yes
Cannot
suppress
Yes
Cannot
suppress
FATAL:
UG-01145_avmm
2015.05.14
BFM Log and Message Procedures
14-35
Avalon-MM Testbench and Design Example
Altera Corporation
Send Feedback